CSafe RKN containers protect temperature-sensitive life-science products during air cargo shipments around the world. It offers unparalleled precision and temperature assurance with intelligent programming and patented VIP insulation technology. Combined with a radiant heating and compressor-driven cooling system, the CSafe RKN autonomously recirculates conditioned air throughout the cargo chamber to encapsulate the payload and provide an optimal layer of protection from temperature risks associated with long-duration shipments in extreme ambient temperature conditions.
CSafe combines proven experience with best-in-class quality performance, and has successfully and safely transported thousands of life-enhancing shipments across the globe, commanding unmatched levels of confidence in our active container fleet.
Superior VIP Insulation | Superior VIP insulation protects payload in the event of a failure |
Air Recirculation System (ARS) | Unique ARS airflow pathway, encapsulating payload with conditioned air on all sides to ensure optimal temperature mapping and operational efficiency |
Temperature Management System (TMS) | Advanced temperature management system (TMS) for autonomous control of innovative heating and compressor driven cooling systems |
Temperature Sensors | Array of 6 temperature sensors throughout cargo compartment |
Temperature Set Points | User-selectable from +4°C to +25°C, in 1°C increments |
Operating Range | -30°C to +49°C |
Temperature Tolerance | +2°C at +5°C |
Battery Run Time | >130 hours for typical shipments |
Automated Data Logging | Cargo compartment temperature, ambient temperature, door opening events and battery status |
Downloadable Data File | Free, downloadable data file via integrated USB port allowing for immediate access to shipment data |
Payload Pallet Required | No |
Pallet Capacity | 1 US or Euro |
Forkliftable | Forkliftable base with flat bottom for roller conveyor transport and aircraft loading |
Regulatory Approval | Suitable for use on all widebody aircraft, with regulatory approval for use on both lower and upper decks |
Visibility Tracker | Integrated real-time visibility tracker |
Payload Volume | 2.0 cubic meters (70 cubic feet) |
Temperature Range* | +2°C to +8°C, +15°C to +25°C |
Internal Dimensions (L x W x H) | 1219 mm x 1273 mm x 1277 mm (48.0 in x 50.1 in x 50.3 in) |
External Dimensions | 2007 mm x 1534 mm x 1626 mm (79 in x 60.4 in x 64.0 in) |
Tare Weight | 646 kg (1425 lb) |
Maximum Payload Weight | 941 kg (2075 lb) |
Maximum Allowable Weight | 1588 kg (3500 lb) |
Power Sources | AC power (100-240 V, 50-60 Hz) Internal batteries (regulatory approved, sealed, non-spillable design that meets Dangerous Goods Regulations) |
Battery Run Time | >130 hours for typical shipments |
Battery Charge Time | 0% to 100% in 4 hours |
Multisystem Charging Cables | • Rechargeable anywhere in the world |
*Coming soon: – 20°C for frozen shipments